Key result
Transthoracic colour-encoded M-mode echocardiography demonstrated two mechanical atrial events for each ventricular mechanical event, identifying atrial flutter in a premature infant.
Case Report (n=1)
Transthoracic colour-encoded M-mode echocardiography can accurately diagnose neonatal atrial flutter when surface ECG is ambiguous.
Answers are grounded in this paper and cite their sources.
May aid neonatal atrial flutter diagnosis when ECG is ambiguous; hypothesis-generating case report requiring prospective validation.
The heart rate of a premature infant had acutely increased during umbilical venous catheterisation. Surface ECG showed a heart rate of 220 beats per minute (bpm). This was interpreted as sinus tachycardia. Transthoracic echocardiography was subsequently performed, demonstrating a moderate patent ductus arteriosus and a small patent oval foramen (PFO), both with left-to-right flow across. In addition, colour-encoded M-mode was used with the line of interrogation crossing the PFO, demonstrating two mechanical atrial events for each ventricular mechanical event …
No takes yet. Share an insight, caveat, or question.
Nadua et al. (2020) conducted a case report in Neonatal atrial flutter (n=1). Transthoracic colour-encoded M-mode echocardiography was evaluated on Demonstration of mechanical atrial events. Transthoracic colour-encoded M-mode echocardiography demonstrated two mechanical atrial events for each ventricular mechanical event, identifying atrial flutter in a premature infant.