Answers are grounded in this paper and cite their sources.
In Brief Objective: It has been claimed that speech recognition with a cochlear implant is dependent on the correct frequency alignment of analysis bands in the speech processor with characteristic frequencies (CFs) at electrode locations. However, the use of filters aligned in frequency to a relatively basal electrode array position leads to significant loss of lower frequency speech information. This study uses an acoustic simulation to compare two approaches to the matching of speech processor filters to an electrode array having a relatively shallow depth within the typical range, such that the most apical element is at a CF of 1851 Hz. Two noise-excited vocoder speech processors are compared, one with CF-matched filters, and one with filters matched to CFs at basilar membrane locations 6 mm more apical than electrode locations. Design: An extended crossover training design examined pre- and post-training performance in the identification of vowels and words in sentences for both processors. Subjects received about 3 hours of training with each processor in turn. Results: Training improved performance with both processors, but training effects were greater for the shifted processor. For a male talker, the shifted processor led to higher post-training scores than the frequency-aligned processor with both vowels and sentences. For a female talker, post-training vowel scores did not differ significantly between processors, whereas sentence scores were higher with the frequency-aligned processor. Conclusions: Even for a shallow electrode insertion, we conclude that a speech processor should represent information from important frequency regions below 1 kHz and that the possible cost of frequency misalignment can be significantly reduced with listening experience. The frequency-place alignment of a cochlear implant is thought to be an important determinant of the benefit derived in speech perception, but the effects of misalignment are much reduced through perceptual plasticity. A second important requirement is that the implant signal information over the range of frequencies that are most important for speech perception. When the electrode array has a relatively shallow insertion, there is a conflict between the preservation of frequency-place alignment and the transmission of the lowest frequencies that are significant for speech. This study compares the costs of frequency-place misalignment to those of low frequency information loss using acoustic simulations in normal hearing listeners. The findings suggest that the deleterious effects of quite substantial frequency-place misalignment will be much reduced with listening experience, and that speech processor mapping should maximize the representation of frequencies important to speech even when this entails a frequency-place misalignment.
No takes yet. Share an insight, caveat, or question.
Faulkner et al. (2006) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: