Answers are grounded in this paper and cite their sources.
Thick-walled concrete orifices are widely used to control outflow rates from stormwater detention basins. There are limited data on stage-discharge relationships for such orifices, particularly for low head and partially full conditions that are relevant to extended detention applications for water quality control. This paper presents laboratory and field testing of stage-discharge relationships for concrete orifices under such conditions. Steady-state and transient drainage curve experiments were conducted in a horizontal flume, and a detention basin with a multistage concrete outlet structure was instrumented to collect drawdown data in the field. For fully submerged conditions, the orifice equation with single-valued discharge coefficient (Cd) does not fit the experimental data, and a model is proposed with Cd increasing nonlinearly from ∼0.55 to ∼0.65 as submergence increases. For partially submerged conditions, an equivalent rectangular weir model provided good fit to the laboratory and field data. The effect of four different orifice models on basin drawdown time was investigated through simulation of a series of synthetic basin and outlet structure configurations. The details of how partially full orifice flow is modeled are important to simulated basin drawdown times; in particular, both linearly interpolated tabular stage-discharge data and other widely-used detention basin software can significantly underestimate drawdown times.
No takes yet. Share an insight, caveat, or question.
Barlow et al. (2015) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: