PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
March 1, 1991Journal of the American Society of Echocardiography266 citationsOpen Access

Tricuspid Annular Motion

View Full Paper
EHEskil HammarströmBWBengt WranneFPFausto J. Pinto

Key Result

Two-dimensional oriented M-mode echocardiography reproducibly measured tricuspid annular motion, with low interobserver (6.19-11.56%) and intraobserver (4.10-7.26%) variability.

Study Design

Type

Observational (n=39)

Structured PICO

Can tricuspid annular motion be reproducibly quantified using two-dimensional oriented M-mode echocardiography?

P
Population
39 subjects, comprising 10 normal adults and 29 patients with left-sided heart disease, evaluated for tricuspid annular motion.
E
Exposure
Measurement of tricuspid annular motion using two-dimensional oriented M-mode echocardiography from the apical view.
O
Outcome
Tricuspid annular motion measurements and reproducibility (interobserver and intraobserver variability).surrogate

Two-dimensional oriented M-mode echocardiography provides a reproducible method for quantifying tricuspid annular motion, offering a diagnostic tool to evaluate right heart function.

Abstract

Triscupid annular motion is related to right ventricular systolic function in the same way mitral annulus motion is related to left ventricular function. Tricuspid annular excursion reflects the longitudinal motion of the right ventricle, and the systolic descent of the anulus correlates with systolic venous inflow to the right atrium. However, it has not been shown clearly how to reproducibly quantify this motion. Therefore we describe a method to measure triscuspid annular motion using two-dimensional oriented M-mode echocardiography from the apical view. We studied a group of 10 normal subjects (mean age, 28.7 years; range, 25 to 38 years) and a group of 29 patients (mean age, 57.2 years; range, 20 to 84 years) with disease of the left side of the heart but no evidence of involvement of the right side of the heart. In each subject, tricuspid and mitral annular motion were measured respectively at their lateral, septal or medial, anterior, and posterior margin points. The total tricuspid annular motion for normal subjects was, as follows: lateral, 24.9 +/- 3.5 mm; medial, 20.1 +/- 2.5 mm; anterior, 21.6 +/- 3.8 mm; and posterior, 22.3 +/- 2.3 mm. Interobserver and intraobserver variability was low, with a coefficient of variance for the different annular points ranging from 6.19% to 11.56% between observers and from 4.10% to 7.26% within observer. We conclude that it is possible to measure tricuspid annular motion with this method in a reproducible way and to use it as a diagnostic tool in evaluating function of the right side of the heart.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Hammarström et al. (1991) conducted an observational in Normal subjects and patients with left-sided heart disease (n=39). Two-dimensional oriented M-mode echocardiography was evaluated on Tricuspid annular motion and measurement reproducibility. Two-dimensional oriented M-mode echocardiography reproducibly measured tricuspid annular motion, with low interobserver (6.19-11.56%) and intraobserver (4.10-7.26%) variability.

synapsesocial.com/papers/6aa2c36b6401f02f7be57056https://doi.org/10.1016/s0894-7317(14)80524-5
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1The role of displacement of the mitral annulus in left atrial filling and emptying in the intact dog1978 · 21 citations
  2. 2The Mechanics of Ventricular Contraction1951 · 131 citations
  3. 3Pulmonary venous flow pattern--its relationship to cardiac dynamics. A pulsed Doppler echocardiographic study.1985 · 296 citations
  4. 4Changes in Configuration of the Ventricular Chambers during the Cardiac Cycle1951 · 65 citations
  5. 5Mitral anulus motion. Relation to pulmonary venous and transmitral flows in normal subjects and in patients with dilated cardiomyopathy.1988 · 239 citations