Key result
Two-layered Poiseuille flow model produces blunted velocity profiles matching experimental blood flow results.
Population
Mathematical model of blood flow through arteries of small diameter and arterioles
Comparison
Two layered Poiseuille flow model vs Classical Poiseuille flow and Poiseuille flow…
Design
Other
Authors
Loading...
May guide microvascular flow simulations; leaves open clinical translation pending in vivo validation.
A two-layered Poiseuille flow model accurately simulates the blunted velocity profiles observed experimentally in blood flow through small arteries.
Chaturani et al. (1976) studied blood flow through arteries of small diameter and arterioles. Two layered Poiseuille flow model vs. classical Poiseuille flow was evaluated on Velocity profiles. A two-layered Poiseuille flow model demonstrated that for small values of couple stress parameters, velocity profiles are blunted and agree with experimental blood flow results.