Key result
The HAT2CH2 score predicts a ~142% higher risk of neurologic events in CIED patients.
Why the study?
The HAT2CH2 score has been evaluated for predicting new-onset atrial fibrillation in several conditions, but never for adverse neurologic events in patients with CIED.
Does the HAT2CH2 score and atrial high-rate episodes (AHRE) duration predict subsequent neurologic events in patients with cardiac implantable electronic devices?
Cohort (n=314)
No
Does the HAT2CH2 score and atrial high-rate episodes (AHRE) duration predict subsequent neurologic events in patients with cardiac implantable electronic devices?
The HAT2CH2 score (cutoff ≥3) and AHRE lasting ≥1 minute are strong, independent predictors of subsequent neurologic events in patients with CIEDs, outperforming the CHA2DS2-VASc score.
Answers are grounded in this paper and cite their sources.
HAT2CH2 score ≥3 was associated with neurologic events in CIED patients; leaves open its role in risk stratification pending prospective validation.
Objectives: The HAT2CH2 score has been evaluated for predicting new-onset atrial fibrillation in several clinical conditions, but never for adverse neurologic events.We aimed to evaluate the effectiveness of HAT2CH2 score in predicting neurologic events in patients with cardiac implantable electronic device (CIED), comparing with atrial high-rate episodes (AHRE).Methods: This case-control study enrolled 314 consecutive patients aged 18 years or older with CIED implantation between January 2015 and April 2021.Patient data were analyzed retrospectively.The primary endpoint was subsequent neurologic events (NE) after implantation.AHRE was defined as > 175 bpm (Medtronic®) lasting ≥ 30 seconds.Variables associated with independent risk of NE were identified using multivariate Cox regression analysis with time-dependent covariates.Results: Patients' median age was 73 years and 61.8% of them were male.During follow-up (median 32 months), 18 NE occurred (incidence rate 2.15/100 patient-years, 95% CI 1.32-4.30).Multiple Cox regression analysis showed that the HAT2CH2 score (HR 2.424, 95% CI 1.683 -3.492, p < 0.001) was an independent predictor for NE.Optimal HAT2CH2 score cutoff value was 3 with highest Youden index (AUC, 0.923; 95% CI, 0.881-0.966;p < 0.001).Both AHRE ≥ 1 minute and HAT2CH2 score ≥ 3 had the highest AUC of the receiver-operating characteristic (0.898, 95% CI, 0.831-0.965,p < 0.001).Significant increase was observed in NE occurrence rates using the HAT2CH2 score (p < 0.001). Conclusion:The HAT2CH2 score and episodes of AHRE lasting ≥ 1 minute are independent risk factors for NE in patients with CIED.
No takes yet. Share an insight, caveat, or question.
Chen et al. (2022) conducted a cohort in Cardiac implantable electronic device (CIED) without history of atrial fibrillation (n=314). HAT2CH2 score was evaluated on Subsequent neurologic events (NE) after implantation (HR 2.424, 95% CI 1.683-3.492, p=<0.001). The HAT2CH2 score independently predicted subsequent neurologic events in patients with cardiac implantable electronic devices.
Synapse has enriched 10 related papers. Consider them for comparative context: