Answers are grounded in this paper and cite their sources.
A nonlinear interference (NLI) monitoring method is proposed for coherent transmission systems by jointly using implementation agreement-defined pilot symbols (PS) and amplitude modulation pilot tone (AMPT). The PS is employed to extract the total noise from the received signal, while the AMPT enables separation of self-channel interference (SCI) and cross-channel interference (XCI) power from amplifier spontaneous emission (ASE) power. In a 60-GBaud dual-polarization quadrature phase-shift keying (DP-QPSK) 1500-km wavelength-division multiplexing (WDM) simulation system, the NLI signal-to-noise ratio (SNR) and NLI-induced optical SNR (OSNR) penalty were estimated with errors less than 0.26/0.07 dB for a single-channel (SCI-only) system and 0.52/0.30 dB for a 5-channel (SCI+XCI) system within a ∼160-µs time window. In a single-channel 60-GBaud DP-QPSK 500-km experimental system, the estimation errors of NLI SNR and OSNR penalty were below 0.45 dB and 0.35 dB, respectively, using ∼ 300-µs data. The proposed PS-AMPT NLI monitoring method exhibits high accuracy and strong compatibility with deployed optical networks.
No takes yet. Share an insight, caveat, or question.
Zuo et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: