Key result
Ablation index normalized by left atrial wall thickness strongly predicted gap formation during pulmonary vein isolation, with a cutoff of 195.6 au/mm indicating effective ablation.
Why the study?
Ablation index does not account for regional variation in wall thickness within the wide antral catheter ablation circle.
Does the ratio of ablation index to atrial wall thickness predict gap formation during pulmonary vein isolation in patients with paroxysmal atrial fibrillation?
Observational (n=102)
Does the ratio of ablation index to atrial wall thickness predict gap formation during pulmonary vein isolation in patients with paroxysmal atrial fibrillation?
Normalizing ablation index by left atrial wall thickness strongly predicts gap formation during pulmonary vein isolation, suggesting a tailored target of 195.6 au/mm for effective ablation.
May inform thickness-adjusted PVI targets to limit gaps; leaves open prospective outcome validation in paroxysmal AF.
BACKGROUND: Ablation index (AI), a novel lesion quality marker, includes contact force, time, and power of radiofrequency (RF) application, but not regional variation in wall thickness within the wide antral catheter ablation (WACA) circle. This study explored the relationships among AI target value, atrial wall thickness, and gap formation within the WACA circle in patients with paroxysmal atrial fibrillation (PAF). METHODS: We evaluated 102 consecutive patients (mean age, 65 ± 9 years) with PAF who underwent AI-guided WACA for ipsilateral pulmonary vein isolation (PVI). Each WACA circle was subdivided into eight segments, and overall 7143 RF applications were delivered, including 125 gaps in PVI ablation lines. For each RF tag within the ablation circle, we collected data on ablation lesion depth surrogates (time of application, delivery power, impedance drop, average contact force, force-time integral [FTI], and AI) and left atrial wall thickness measured by multidetector computer tomography scanning. RESULTS: The anterior and roof walls were the thickest segments of the ablation circle, in which 85.8% of gaps concentrated, while the posterior and inferior walls were the thinnest. Gap formation was significantly associated with FTI, AI, wall thickness, FTI/wall thickness, and AI/wall thickness. AI/wall thickness had the highest predictive value for gap formation, with a cutoff of 195.6 au/mm for effective ablation. CONCLUSIONS: In AI-guided PVI of PAF, AI/wall thickness by normalizing myocardial thickness variation along the WACA circle was a strong predictor of gap formation, with a target of 195.6 au/mm appearing suitable for effective ablation.
No takes yet. Share an insight, caveat, or question.
Wang et al. (2020) conducted an observational in paroxysmal atrial fibrillation (n=102). Ablation index normalized by wall thickness was evaluated on Gap formation within the wide antral catheter ablation circle. Ablation index normalized by left atrial wall thickness strongly predicted gap formation during pulmonary vein isolation, with a cutoff of 195.6 au/mm indicating effective ablation.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: