Low-cycle fatigue behaviour of 304 stainless steel has been studied at 20°C and -196°C. The results obtained are summarized as follows:(1) The low-cycle fatigue life depends on the mechanical properties which change according to the amount of α'-martensite induced by increasing number of fatigue cycles.(2) The low-cycle fatigue life curves (Δεt/2-Nf) obtained agree fairly with the curves calculated by Manson's equation.(3) The fatigue cracks initiates at about 20% of the fatigue life at 20°C, while it initiates at about 70% of the fatigue life at -196°C.
No takes yet. Share an insight, caveat, or question.
NAKAMURA et al. (1982) studied this question.
Synapse has enriched 2 closely related papers on similar clinical questions. Consider them for comparative context: