A novel closed-loop signal detection method is proposed to optimize the high-frequency performance of the optical voltage sensors (OVSs) based on Pockels effect. First, a timing sequence control method is introduced to accomplish the whole closed-loop process within one transit period of the optical propagation path, which can ensure the system high dynamic response with high-frequency signal input. Then, we investigate the frequency spectrum of closed-loop error, and design the signal processing before the closed-loop controller with a low pass filter to enhance the signal to noise ratio without reducing the system bandwidth. Furthermore, considering the optical parameter uncertainty and the unavoidable external disturbance, a closed-loop control algorithm is presented to optimize the steady state accuracy and dynamic performance of OVSs. The experimental results show that the closed-loop steady state accuracy of sine response, slope response, and acceleration measurement with the 20-kHz input signal are basically consistent with the static accuracy, and the relative measurement error of OVS is ±0.1% with the applied voltage over 100 V, which verify the effectiveness of the proposed detection scheme.
No takes yet. Share an insight, caveat, or question.
Liu et al. (2017) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: