Key result
Dynamic hip screw fixation linked to lower postoperative hemoglobin by day 5 versus hip hemiarthroplasty.
Why the study?
What is the trajectory of postoperative hemoglobin levels in patients undergoing fixation of femoral neck fracture?
Observational (n=178)
What is the trajectory of postoperative hemoglobin levels in patients undergoing fixation of femoral neck fracture?
Mean Difference: 31.1
p-value: p=<0.001
Hemoglobin levels continue to drop until day-2 post-operatively in patients with femoral neck fractures, suggesting day-1 monitoring underestimates the lowest hemoglobin value.
May support extended hemoglobin monitoring beyond day 1 after femoral neck fracture surgery; leaves open transfusion implications by fixation type.
OBJECTIVES: The aim of this study was to analyze the changes in hemoglobin level and to determine a suitable timeline for post-operative hemoglobin monitoring in patients undergoing fixation of femoral neck fracture. PATIENTS AND METHODS: Patients who underwent either dynamic hip screw (DHS) fixation (n = 74, mean age: 80 years) or hip hemiarthroplasty (n = 104, mean age: 84 years) for femoral neck fracture were included into the study. The hemoglobin level of the patients was monitored perioperatively. RESULTS: Analysis found a statistically and clinically significant mean drop in hemoglobin of 31.1 g/L over time from pre-operatively (D0) to day-5 post-operatively (p < 0.001), with significant reductions from D0 to day-1 and day-1 to day-2 (p < 0.001). At each post-operative time point, DHS patients had lower hemoglobin values over hemiarthroplasty patients (p = 0.046). CONCLUSION: The decrease in hemoglobin in the first 24-h post-operative period (D0 to day-1) is an underestimation of the ultimate lowest value in hemoglobin found at day-2. Relying on the day-1 hemoglobin could be detrimental to patient care. We propose a method of predicting patients likely to be transfused, and recommend a protocol for patients undergoing femoral neck fracture surgery to standardize postoperative hemoglobin monitoring. LEVEL OF EVIDENCE: Level IV Prognostic study.
No takes yet. Share an insight, caveat, or question.
Nagra et al. (2016) conducted an observational in Femoral neck fracture (n=178). Dynamic hip screw (DHS) fixation vs. Hip hemiarthroplasty was evaluated on Change in hemoglobin level from pre-operatively to day-5 post-operatively (Mean drop 31.1 g/L, p=<0.001). Dynamic hip screw fixation was associated with lower postoperative hemoglobin values compared to hip hemiarthroplasty (p=0.046), with an overall mean drop of 31.1 g/L by day 5 (p<0.001).