Key result
Non-invasive Doppler evaluation of left internal mammary artery grafts showed that diastolic/systolic velocity ratios were smaller in patients with significant graft stenosis.
Why the study?
Can a non-invasive Doppler technique through the supraclavicular approach accurately detect flow velocity patterns and patency in left internal mammary artery grafts compared to coronary angiography?
Observational (n=37)
Can a non-invasive Doppler technique through the supraclavicular approach accurately detect flow velocity patterns and patency in left internal mammary artery grafts compared to coronary angiography?
Non-invasive Doppler ultrasound can detect distinct flow velocity patterns that differentiate between patent and stenosed left internal mammary artery grafts.
Answers are grounded in this paper and cite their sources.
Diastolic/systolic velocity ratios were associated with LIMA stenosis; leaves open the utility of supraclavicular Doppler for graft surveillance pending prospective validation.
The capability of Doppler to detect patency of left internal mammary artery grafts through the supraclavicular approach was evaluated. A total of 37 patients with a left internal mammary artery graft to the left anterior descending artery were divided into three groups, according to postoperative coronary angiographic studies. Group 1 comprised 20 patients with no significant stenosis of the left internal mammary artery and subtotal or total obstruction in the left anterior descending coronary artery proximal to the anastomotic site. There were ten patients with no significant stenosis of the left internal mammary artery and 75% stenosis of the left anterior descending coronary artery in group 2. Seven patients with significant stenosis of the left internal mammary artery formed group 3. Analysis of the flow velocity pattern in the left internal mammary artery graft included: (1) systolic peak velocity (SPV), (2) diastolic peak velocity (DPV), (3) systolic time velocity integral (SI), (4) diastolic time velocity integral (DI), (5) diastolic peak velocity/systolic peak velocity and (6) diastolic time velocity integral/diastolic time velocity integral+systolic time velocity integral. There were no significant differences in systolic peak velocity and systolic time velocity integral between the three groups. The diastolic peak velocity and diastolic time velocity integral were greater in group 1 than in groups 2 (P < 0.05, P < 0.01) and 3 (P < 0.05). The diastolic peak velocity/systolic peak velocity and diastolic time velocity integral/diastolic time velocity integral+systolic time velocity integral ratios in group 3 were significantly smaller than in groups 1 and 2 (P < 0.01).(ABSTRACT TRUNCATED AT 250 WORDS)
No takes yet. Share an insight, caveat, or question.
Nasu et al. (1994) conducted an observational in Left internal mammary artery graft to the left anterior descending artery (n=37). Non-invasive Doppler technique vs. Different degrees of stenosis was evaluated on Flow velocity pattern in the left internal mammary artery graft (p=<0.01). Non-invasive Doppler evaluation of left internal mammary artery grafts showed that diastolic/systolic velocity ratios were smaller in patients with significant graft stenosis.
Synapse has enriched 10 related papers. Consider them for comparative context: