Key result
A minimally invasive off-pump redo procedure using the NeoChord device successfully treated severe mitral valve regurgitation relapse, resulting in only trivial residual regurgitation.
Why the study?
Redo surgeries after mitral valve repair are technically demanding, and the use of the NeoChord device for redo procedures after conventional surgical repair has not been well established.
Case Report (n=1)
The NeoChord device represents a feasible off-pump treatment option for patients requiring redo surgery for recurrent mitral regurgitation after prior surgical repair.
RATIONALE: Redo surgeries after mitral valve repair are technically demanding. Procedures applying the NeoChord device (NeoChord Inc, St. Louis Park, MN) have proven to be safe and feasible in selected patients requiring mitral valve repair due to a leaflet prolapse or flail. However, its use for redo procedures after conventional surgical repair has not been well established yet. PATIENT CONCERNS: We report the case of a 57-year-old man who presented with dyspnea upon exertion. The patient had undergone a minimally invasive surgical mitral valve repair because of a flail leaflet of the segments segment 2 of the posterior mitral valve leaflet (P2)/segment 3 of the posterior mitral valve leaflet (P3) 4 years before. DIAGNOSES: Transesophageal echocardiography identified a relapse of severe mitral valve regurgitation. The recurring regurgitant jet was caused by a flail leaflet due to newly ruptured native chords. INTERVENTIONS: After discussion in an interdisciplinary heart team, we performed a minimally invasive off-pump redo procedure applying the NeoChord device under three-dimensional transesophageal echocardiographic guidance. OUTCOMES: The echocardiographic result with only trivial residual mitral regurgitation as well as the further clinical course of the patient were favorable. LESSONS: As redo surgery after minimally invasive mitral valve repair is challenging, the NeoChord device represents a novel treatment option that does not require cardiopulmonary bypass.
No takes yet. Share an insight, caveat, or question.
Blessberger et al. (2021) conducted a case report in Relapse of severe mitral valve regurgitation (n=1). Minimally invasive off-pump redo procedure applying the NeoChord device was evaluated on Echocardiographic result and clinical course. A minimally invasive off-pump redo procedure using the NeoChord device successfully treated severe mitral valve regurgitation relapse, resulting in only trivial residual regurgitation.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: