This is the authors' abstract. We don't add key points for this paper.
Tomographic imaging modalities are being increasingly used to quantify internal characteristics of objects for a wide range of applications, from medical imaging to materials science research. However, such measurements are typically presented without an assessment being made of their associated variance or confidence interval. In particular, noise in raw scan data places a fundamental lower limit on the variance and bias of measurements made on the reconstructed 3D volumes. In this paper, the simulation-extrapolation technique, which was originally developed for statistical regression, is adapted to estimate the bias and variance for measurements made from a single scan. The application to x-ray tomography is considered in detail and it is demonstrated that the technique can also allow the robustness of automatic segmentation strategies to be compared.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Robert S. Bradley (2016) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: