Key result
Fractal microelectronics for low-voltage PFA increases ablation depth ~39% and selectively ablates cardiomyocytes in beagles.
Why the study?
Current pulsed field ablation uses millimeter-scale rigid electrodes delivering thousands of volts without integrated sensing capabilities.
Does catheter-integrated fractal microelectronics for low-voltage PFA improve ablation depth and safety in living beagles?
Does catheter-integrated fractal microelectronics for low-voltage PFA improve ablation depth and safety in living beagles?
Catheter-integrated fractal microelectronics enable low-voltage pulsed field ablation with increased ablation depth and tissue selectivity, potentially improving the safety and efficacy of PFA for atrial fibrillation.
Answers are grounded in this paper and cite their sources.
May enable integrated sensing during PFA; leaves open clinical benefits pending larger prospective trials.
Pulse field ablation (PFA) has become a popular technique for treating tens of millions of patients with atrial fibrillation, as it avoids many complications associated with traditional radiofrequency ablation. However, currently, limited studies have used millimeter-scale rigid electrodes modified from radiofrequency ablation to apply electrical pulses of thousands of volts without integrated sensing capabilities. Herein, we combine fractal microelectronics with biomedical catheters for low-voltage PFA, detection of electrode–tissue contact, and interventional electrocardiogram recording. The fractal configuration increases the ratio of the microelectrode insulating edge to area, which facilitates the transfer of current from the microelectrode to the tissue, increasing the ablation depth by 38.6% at 300 V (a 10-fold reduction compared to current technology). In vivo ablation experiments on living beagles successfully block electrical conduction, as demonstrated by voltage mapping and electrical pacing. More impressively, this study provides the first evidence that microelectrodes can selectively ablate cardiomyocytes without damaging nerves and blood vessels, greatly improving the safety of PFA. These results are essential for the clinical translation of PFA in the field of cardiac electrophysiology.
No takes yet. Share an insight, caveat, or question.
Xu et al. (2025) studied Atrial fibrillation. Catheter-integrated fractal microelectronics for low-voltage pulse field ablation vs. Current technology (millimeter-scale rigid electrodes) was evaluated on Ablation depth and selective ablation of cardiomyocytes. Catheter-integrated fractal microelectronics for low-voltage pulse field ablation increased ablation depth by 38.6% at 300 V and selectively ablated cardiomyocytes in living beagles.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: