Answers are grounded in this paper and cite their sources.
• Fibre reinforcement affects fracture resistance in endodontically treated premolars • Polyethylene fibres and glass fibre posts show distinct biomechanical behaviour in vitro • Meta-analysis reveals consistent mechanical trends despite laboratory heterogeneity • Failure patterns vary according to the fibre reinforcement strategy used • Laboratory evidence may assist restorative decisions with acknowledged clinical limits To systematically compare the biomechanical performance reported in in vitro studies of endodontically treated maxillary premolars restored with glass fiber posts or polyethylene fiber reinforcement, focusing on fracture resistance and failure pattern. The review protocol was prospectively registered in PROSPERO (CRD420251008728). A comprehensive electronic search was conducted without restrictions. Eligible studies were in vitro investigations using extracted human maxillary premolars restored with either polyethylene fiber reinforcement or glass fiber posts and subsequently subjected to fracture testing. The primary outcomes were fracture resistance (Newtons) and failure pattern, classified as unfavorable (root or sub-bony fracture) or favorable (crown or suprabony fracture). Data were synthesized using random-effects models and expressed as mean difference or risk ratio, with heterogeneity assessment. Certainty of evidence was evaluated using the GRADE approach. Five in vitro studies fulfilled the inclusion criteria. Polyethylene fiber reinforcement showed significantly higher fracture resistance than glass fiber posts (mean difference −69.84 N; 95% confidence interval −135.96 to −3.71; I² = 6%). Sensitivity analysis confirmed the robustness of this finding. No significant difference was observed in the proportion of unfavorable fractures between groups (risk ratio 0.92; 95% confidence interval 0.69 to 1.24; I² = 32%). Certainty of evidence was assessed separately for each outcome and should be interpreted in light of the preclinical nature of the included evidence. Based on the available in vitro evidence, polyethylene fiber reinforcement was associated with greater fracture resistance than glass fiber posts in endodontically treated maxillary premolars, whereas no significant difference was found between the two strategies in the proportion of unfavorable fractures. These findings suggest a biomechanical advantage of polyethylene fiber reinforcement in load-bearing capacity, but do not indicate a clear difference in fracture reparability.
No takes yet. Share an insight, caveat, or question.
Matos et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: