The Journal of Bone and Joint Surgery. British volumeVol. 79-B, No. 2 Topic for DebateFree AccessFatigue failure of cancellous bone: a possible cause of implant migration and loosening*M. Taylor, K. E. TannerM. TaylorResearch AssistantSearch for more papers by this author, K. E. TannerReaderSearch for more papers by this authorPublished Online:1 Mar 1997https://doi.org/10.1302/0301-620X.79B2.0790181AboutSectionsPDF/EPUB ToolsAdd to FavouritesDownload CitationsTrack CitationsPermissions ShareShare onFacebookTwitterLinked InRedditEmail FiguresReferencesRelatedDetailsCited byInfluence of the angle between tibial and prosthesis mechanical axes on tibial bone remodeling in total knee arthroplasty12 July 2022 | Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, Vol. 236, No. 8Advances in machining of hard tissues – From material removal mechanisms to tooling solutionsInternational Journal of Machine Tools and Manufacture, Vol. 172Monitoring the reduction and maintenance of periprosthetic bone tissue in cementless primary hip endoprosthesis with alendronate therapy20 November 2021 | Archives of Public Health, Vol. 13, No. 2Influence of alendronate therapy on the results of densitometric examination after implantation of total hip endoprosthesis20 June 2021 | Archives of Public Health, Vol. 13, No. 1Femoral revision knee Arthroplasty with Metaphyseal sleeves: the use of a stem is not mandatory of a structural point of view26 April 2020 | Journal of Experimental Orthopaedics, Vol. 7, No. 1Short stems for total hip replacement among middle-aged patients19 March 2020 | International Orthopaedics, Vol. 44, No. 5Three-Dimensional Finite Analysis of the Optimal Alignment of the Tibial Implant in Unicompartmental Knee ArthroplastyJournal of Nippon Medical School, Vol. 87, No. 2Experimental Evaluation of Vertebral Strain in Lumbar Total Disc Replacement16 October 2019 | Experimental Mechanics, Vol. 60, No. 1Effect of loading frequency on deformations at the bone–implant interface27 September 2019 | Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, Vol. 233, No. 12The risk of loosening of extramedullary fracture fixation devicesInjury, Vol. 50Time-dependent behaviour of bone accentuates loosening in the fixation of fractures using bone-screw systemsS. Xie, K. Manda, P. Pankaj25 October 2018 | Bone & Joint Research, Vol. 7, No. 10Optimum stem length for mitigation of periprosthetic fracture risk following primary total knee arthroplasty: a finite element study3 November 2016 | Knee Surgery, Sports Traumatology, Arthroscopy, Vol. 26, No. 5Improving stress shielding following total hip arthroplasty by using a femoral stem made of β type Ti-33.6Nb-4Sn with a Young’s modulus gradationJournal of Biomechanics, Vol. 63Influence of the fixation region of a press–fit hip endoprosthesis on the stress–strain state of the “bone–implant” systemComputers in Biology and Medicine, Vol. 84Total arthroplasty of basal thumb joint with Elektra prothesis: an in vitro analysis19 July 2016 | Journal of Hand Surgery (European Volume), Vol. 41, No. 9Finite Element Analysis of Mobile-bearing Unicompartmental Knee ArthroplastyChinese Medical Journal, Vol. 128, No. 21Failure analysis of C-5 after total disc replacement with ProDisc-C at 1 and 2 levels and in combination with a fusion cage: finite-element and biomechanical modelsJournal of Neurosurgery: Spine, Vol. 22, No. 6In-vitro biomechanical evaluation of stress shielding and initial stability of a low-modulus hip stem made of β type Ti-33.6Nb-4Sn alloyMedical Engineering & Physics, Vol. 36, No. 12Trabecular bone density of the proximal tibia as it relates to failure of a total knee replacementM. A. Ritter, K. E. Davis, S. R. Small, J. G. Merchun, A. Farris1 November 2014 | The Bone & Joint Journal, Vol. 96-B, No. 11Periprothetische femorale Knochenreaktion nach schenkelhalserhaltender Hüftendoprothetik27 March 2011 | Der Orthopäde, Vol. 40, No. 7Torsional Stability of a Polished, Collarless, Tapered Total Replacement Hip Joint Stem under Vertical Load: An In Vitro Investigation29 July 2010 | Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, Vol. 225, No. 1Addition of a short central extension to surface cemented tibial trays in primary TKA: An in vitro study of the effect on initial fixation stability and its relationship to supporting bone densityClinical Biomechanics, Vol. 23, No. 4Influence of the Loading Rate on the Cyclic Deformation Behaviour and the Damage Accumulation of Cortical Bone Specimens Under Three-Point BendingAdvanced Engineering Materials, Vol. 9, No. 12Fatigue of the cement/bone interface: The surface texture of bone and loosening1 January 2006 | Journal of Biomedical Materials Research Part B: Applied Biomaterials, Vol. 76B, No. 2Cancellous Bone Strains Indicate Efficacy of Stem Augmentation in Constrained Condylar KneesClinical Orthopaedics and Related Research, Vol. 440, No. Damage Rate is a Predictor of Fatigue Life and Creep Strain Rate in Tensile Fatigue of Human Cortical Bone Samples28 September 2004 | Journal of Biomechanical Engineering, Vol. 127, No. 2The Chetranjan Ranawat Award: Tibial Component Failure Mechanisms in Total Knee ArthroplastyClinical Orthopaedics & Related Research, Vol. 428Effects of Stem Design and Pre-Cooling Prostheses on the Heat Generated by Bone Cement in an In Vitro Model25 June 2016 | Journal of International Medical Research, Vol. 30, No. 3Monitoring of Periprosthetic BMD After Uncemented Total Hip Arthroplasty with Dual‐Energy X‐Ray Absorptiometry—a 3‐Year Follow‐Up Study2 December 2009 | Journal of Bone and Mineral Research, Vol. 16, No. 6Migration, Particles, and Fluid PressureClinical Orthopaedics and Related Research, Vol. 352 Vol. 79-B, No. 2 Metrics History Published online 1 March 1997 Published in print 1 March 1997 InformationCopyright © 1997, The British Editorial Society of Bone and Joint Surgery: All rights reservedPDF download
No takes yet. Share an insight, caveat, or question.
Taylor et al. (1997) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: