Recent advancements in high-field-strength MRI scanners, particularly with the emergence of commercially available 5-T and 7-T MRI scanners, have opened new avenues for exploration.However, these new scanners must prove their efficiency compared to their lower-field-strength predecessors while also showcasing novel capabilities that surpass those of lower-field-strength scanners.The clinical relevance of cardiovascular MRI is indisputable, enabling a comprehensive evaluation of structural heart diseases including myocardial function, perfusion, hemodynamics, and tissue characterization such as myocardial fibrosis or edema (1, 2).Coronary MR angiography (CMRA) is inferior to coronary CT angiography (CCTA).The critical question now is whether these high-fieldstrength MRI scanners can accurately depict coronary anatomy and help assess the presence and severity of coronary artery disease (CAD).In this issue of Radiology, Lu and Miao et al (3) tried to answer this question and assessed the feasibility and clinical application of 5-T noncontrast Dixon whole-heart CMRA.In their prospective study, the presence and severity of CAD were evaluated with CMRA using a 3-T spectral attenuated inversion recovery sequence at routine spatial resolution (3-T spair- routine ), a 3-T Dixon sequence at routine spatial resolution (3T Dixon-routine ), a 5-T Dixon sequence at routine spatial resolution (5T Dixon-routine ), and a 5-T Dixon sequence at high spatial resolution (5T Dixon-high ).CCTA served as the reference standard for comparison.The authors found that the image quality score of the 5T Dixon-routine method was superior to those of both the 3T SPAIR-routine and the 3T Dixon-routine methods (P<.001 for both), while it was comparable to that of the 5T Dixon-high method (P=0.60).The 5T Dixon-high method demonstrated higher per-segment sensitivity for coronary artery calcium compared to the 5T Dixon-routine method (78.3% vs. 53.3%,P<.001), though both showed similar specificity (98.6% vs. 98.6%,P>.99).In terms of grading the severity of CAD, 5T Dixon-routine exhibited greater consistency with CCTA than 3T SPAIR-routine (κ = 0.46 vs 0.13) and 3T Dixon-routine (κ = 0.55 vs 0.42).For the identification of stenosis of at least 50%, 5T Dixon-routine showed higher per-patient sensitivity (88.9% vs 55.6%, P = .55),specificity (86.5% vs. 62.2%, P = .01),and accuracy (87.0% vs. 60.9%,P = .18)compared to 3T SPAIR-routine .Similar trends were observed when comparing 5T Dixon-routine with 3T Dixon-routine , with 5T Dixon-routine
No takes yet. Share an insight, caveat, or question.
Rahsepar et al. (2024) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: