In this paper, a multipulse ac–dc converter fed multilevel inverter (MLI)-based indirect vector controlled induction motor drive (IVCIMD) is proposed for medium-power application. A 54-pulse ac–dc converter is utilized at the supply side to suppress the input current total harmonic distortion, as per the IEEE-519 standard. Mainly three separate isolated transformers are utilized and each transformer is configured as an 18-pulse ac–dc converter. Due to the phase shift in primary windings, these three transformers are reconfigured as a 54-pulse ac–dc converter. A 15-level binary-based cascaded MLI is utilized at the motor side to enhance the required performance of IVCIMD. A 15-level inverter is switched at fundamental frequency, which ensures the very low switching losses in the proposed IVCIMD. A modified nearest level modulation strategy is proposed to achieve fundamental switching frequency. The performance of the proposed IVCIMD is simulated at various operating conditions by utilizing Simulink/MATLAB platform. Simulated results are validated with experimental results on a developed prototype in the laboratory to show its usefulness for medium-power applications.
No takes yet. Share an insight, caveat, or question.
Singh et al. (2018) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: