Key result
Self-expanding TAVR shows similar LVMi changes compared to balloon-expandable valves.
Why the study?
There are limited reports on the impact of prosthesis-patient mismatch on left ventricular hypertrophy regression after TAVR.
Does the use of supra-annular self-expanding prostheses compared to intra-annular balloon-expandable prostheses improve left ventricular hypertrophy regression in patients undergoing TAVR?
Cohort (n=168)
Does the use of supra-annular self-expanding prostheses compared to intra-annular balloon-expandable prostheses improve left ventricular hypertrophy regression in patients undergoing TAVR?
Self-expanding and balloon-expandable TAVR prostheses yield similar degrees of left ventricular hypertrophy regression at intermediate follow-up, despite differences in post-procedural hemodynamics and prosthesis-patient mismatch.
Similar LV mass regression does not support prosthesis selection by type; leaves open long-term outcome differences in RCTs.
There are limited reports on the impact of prosthesis-patient mismatch (PPM) on the regression of left ventricular hypertrophy (LVH) after transcatheter aortic valve replacement (TAVR). We compared the relative effects of supra-annular, self-expanding (SE) versus intra-annular, balloon-expandable (BE) prostheses on TAVR LVH regression. Regression of left ventricular mass index (LVMi) was evaluated in 168 consecutive TAVR patients, including 60 treated with SE valves (Evolut series) and 108 treated with BE valves (Sapien 3). All patients had LVH determined at baseline by echocardiography and had repeat LVMi measurements at a mean follow-up time of 707 ± 528 days. SE patients were more likely female (68.3% vs 46.3%, p=0.007), but otherwise, the 2 cohorts did not differ with respect to baseline demographics and Society of Thoracic Surgeons risk score. SE patients had a higher effective orifice area indexed to body surface area after TAVR (0.98 ± 0.29 vs 0.86 ± 0.25 cm²/m², p=0.006), with lower mean aortic valve gradients (9.9 ± 6.5 vs 12.8 ± 5.8 mm Hg, p=0.003) and a lower prevalence of moderate/severe PPM (33.3% vs 49.1%, p=0.049). On follow-up, changes in LVMi were similar between the SE and BE groups, with similar absolute changes in LVMi (19.2 ± 26.8 vs 21.9 ± 31.7 g/m 2 , p=0.578) and relative LVMi decrease (14.0 ± 19.5 vs 16.2% ± 24.2%, p=0.547). No difference in LVMi regression was also noted comparing combined SE/BE patients with moderate/severe PPM versus those without PPM. In conclusion, despite differences in effective orifice area indexed to body surface area, mean aortic valve gradient, and PPM after TAVR, the degree of LVH regression during intermediate follow-up did not differ between patients receiving supra-annular SE and intra-annular BE prostheses.
No takes yet. Share an insight, caveat, or question.
Azemi et al. (2024) conducted a cohort in Left ventricular hypertrophy after transcatheter aortic valve replacement (n=168). Self-expanding (SE) prostheses vs. Balloon-expandable (BE) prostheses was evaluated on Absolute change in left ventricular mass index (LVMi) (p=0.578). Self-expanding TAVR prostheses resulted in similar absolute changes in left ventricular mass index compared to balloon-expandable prostheses (19.2 vs 21.9 g/m², p=0.578).