Why the study?
Does a 23-mm balloon-expandable valve compared to a 26-mm self-expanding valve improve survival or echocardiographic outcomes in patients with small aortic annuli undergoing TAVI?
Does a 23-mm balloon-expandable valve compared to a 26-mm self-expanding valve improve survival or echocardiographic outcomes in patients with small aortic annuli undergoing TAVI?
In patients with small aortic annuli, balloon-expandable and self-expanding valves yield similar intermediate-term survival, despite higher rates of prosthesis-patient mismatch and elevated gradients with balloon-expandable valves.
Answers are grounded in this paper and cite their sources.
Similar clinical outcomes observed with BE versus SE valves; leaves open long-term hemodynamic durability in small annuli.
. A total of 337 patients treated with a 23-mm BE valve (SAPIEN 3, Ultra) were compared with 236 patients treated with a 26-mm SE valve (Evolut series). Valve-in-valve cases were excluded, and late echo follow-up (mean 674 ± 438 days) was assessed in a subset of 292 patients (51.0%). Well-matched BE and SE cohorts did not differ with respect to major in-hospital outcomes, other than a borderline increase in vascular complications and composite bleeding in patients with SE. Patients with BE had a higher incidence of severe PPM on discharge echocardiography (16.9% vs 6.8%, p <0.002). The mean AV gradient at 30 days was higher for patients with BE (12.2 ± 4.2 vs 6.2 ± 7.9 mm Hg, p <0.001) and at late follow-up (14.0 ± 8.2 vs 7.2 ± 3.5 mm Hg, p <0.001). The follow-up left ventricular ejection fraction and incidence of >mild aortic insufficiency were similar. All-cause mortality for the 2 cohorts was similar, with an overall mean (95% confidence interval) survival time of 61.2 months (57.8 to 64.5; p = 0.98). There were no significant survival differences between combined patients with BE and SE with no, moderate, or severe PPM, with an overall mean (95% confidence interval) survival time of 32.5 (30.5 to 34.5) months combining valve types (p = 0.23). In conclusion, despite an increased incidence of PPM with higher mean AV gradients that persist on late echocardiography in the BE cohort, patients with BE and SE with small aortic annuli have similar clinical outcomes at intermediate follow-up. Moderate and severe PPM had no impact on survival at a mean follow-up of 32.5 months.
No takes yet. Share an insight, caveat, or question.
Mosleh et al. (2023) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: