Key result
Balloon-expandable valves show similar 1-year mortality to self-expanding valves in severe aortic stenosis.
Why the study?
No data existed comparing contemporary iterations of balloon-expandable Edwards SAPIEN 3/Ultra and self-expanding Medtronic Evolut PRO/R34 valves, particularly in patients with a small aortic annulus.
Does self-expanding transcatheter aortic valves improve 1-year all-cause mortality compared to balloon-expandable valves in patients with severe symptomatic aortic stenosis?
Cohort (n=1,673)
Yes
Does self-expanding transcatheter aortic valves improve 1-year all-cause mortality compared to balloon-expandable valves in patients with severe symptomatic aortic stenosis?
Contemporary self-expanding and balloon-expandable transcatheter aortic valves offer similar midterm survival, but self-expanding valves may provide a survival benefit in patients with small annuli.
Background No data currently exist comparing the contemporary iterations of balloon‐expandable (BE) Edwards SAPIEN 3/Ultra and the self‐expanding (SE) Medtronic Evolut PRO/R34 valves. The aim of the study was the comparison of these transcatheter heart valves with emphasis on patients with small aortic annulus. Methods and Results In this retrospective registry, periprocedural outcomes and midterm all‐cause mortality were analyzed. A total of 1673 patients (917 SE versus 756 BE) were followed up for a median of 15 months. A total of 194 patients died (11.6%) during follow‐up. SE and BE groups showed similar survival at 1 (92.6% versus 90.6%) and 3 (80.3% versus 85.2%) years ( P log‐rank =0.136). Compared with the BE group, patients treated with the SE device had lower peak (16.3±8 mm Hg SE versus 21.9±8 mm Hg BE) and mean (8.8±5 mm Hg SE versus 11.5±5 mm Hg BE) gradients at discharge. Conversely, the BE group demonstrated lower rates of at least moderate paravalvular regurgitation postoperatively (5.6% versus 0.7% for SE and BE valves, respectively; P <0.001). In patients treated with small transcatheter heart valves (≤26 mm for SE and ≤23 mm for BE; N=284 for SE and N=260 for BE), survival was higher among patients treated with SE valves at both 1 (96.7% SE versus 92.1% BE) and 3 (91.8% SE versus 82.2% BE) years ( P log‐rank =0.042). In propensity‐matched patients treated with small transcatheter heart valve, there remained a trend for higher survival among the SE group at both 1 (97% SE versus 92.3% BE) and 3 years (91.8% SE versus 78.7% BE), P log‐rank =0.096). Conclusions Real‐world comparison of the latest‐generation SE and BE devices demonstrated similar survival up to 3 years’ follow‐up. In patients with small transcatheter heart valves, there may be a trend for improved survival among those treated with SE valves.
No takes yet. Share an insight, caveat, or question.
Kalogeras et al. (2023) conducted a cohort in Severe, symptomatic aortic stenosis (n=1,673). Balloon-expandable transcatheter heart valves vs. Self-expanding transcatheter heart valves was evaluated on 1-year all-cause mortality (HR 1.25, 95% CI 0.93-1.68, p=0.137). Balloon-expandable and self-expanding transcatheter aortic valves demonstrated similar 1-year all-cause mortality (9.4% vs 7.4%, HR 1.25, p=0.137) in patients with severe aortic stenosis.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: