Key result
TAVR linked to a ~2.5% improvement in GLS at one year in severe aortic stenosis.
Why the study?
LV mechanics are impaired in severe AS, and while TAVR could positively impact them, the immediate and long-term effects on LV function recovery assessed by myocardial deformation parameters remained to be evaluated.
Does transcatheter aortic valve replacement (TAVR) improve left ventricular global longitudinal strain in patients with severe aortic stenosis?
Observational (n=119)
Yes
Does transcatheter aortic valve replacement (TAVR) improve left ventricular global longitudinal strain in patients with severe aortic stenosis?
Absolute Event Rate: -17.1% vs -14.6%
p-value: p=<0.001
TAVR is associated with immediate and sustained improvements in left ventricular global longitudinal strain at 1 year in patients with severe aortic stenosis.
GLS recovery after TAVR was associated with survival; leaves open whether strain imaging refines risk stratification in severe AS subtypes.
PURPOSE: Left ventricular (LV) mechanics are impaired in patients with severe aortic stenosis (AS). Transcatheter aortic valve replacement (TAVR) has become a widespread technique for patients with severe AS considered inoperable or high risk for open surgery. This procedure could have a positive impact in LV mechanics. The aim of the study was to evaluate the effect of TAVR on LV function recovery, as assessed by myocardial deformation parameters, both immediately and in the long term. METHODS: One-hundred nineteen consecutive patients (81.2 ± 6.9 years, 50.4% female) from 10 centres in Europe with severe AS who successfully underwent TAVR with either a self-expanding CoreValve (Medtronic, Minneapolis, MN, USA) or a mechanically expanded Lotus valve (Boston Scientific, Natick, MA, USA) were enrolled in a prospective observational study. A complete echocardiographic examination was performed prior to device implantation, before discharge and 1 year after the procedure, including the assessment of LV strain using standard 2D images. RESULTS: Between baseline and discharge, only a modest but statistically significant improvement in GLS (global longitudinal strain) could be seen (GLS% -14.6 ± 5.0 at baseline; -15.7 ± 5.1 at discharge, p = 0.0116), although restricted to patients in the CoreValve group; 1 year after the procedure, a greater improvement in GLS was observed (GLS% -17.1 ± 4.9, p < 0.001), both in the CoreValve and the Lotus groups. CONCLUSIONS: Immediate and sustained improvement in GLS was appreciated after the TAVR procedure. Whether this finding continues to be noted in a more prolonged follow-up and its clinical implications need to be assessed in further studies.
No takes yet. Share an insight, caveat, or question.
Santos et al. (2019) conducted an observational in Severe aortic stenosis (n=119). Transcatheter aortic valve replacement (TAVR) vs. Baseline (pre-procedure) was evaluated on Global longitudinal strain (GLS) at 1 year (p=<0.001). Transcatheter aortic valve replacement in patients with severe aortic stenosis significantly improved global longitudinal strain from -14.6% at baseline to -17.1% at 1 year (p<0.001).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: