Stacking fault energies are computed in ionic crystals with spinel structure (normal and inverse) for combinations which do not disturb stoichiometry: displacement vector a/4〈110〉 on the {100}, {110}, {111}, and {112} fault planes. The fault with lowest energy in the inverse spinel structure is (110) a/4 [110] (completely equivalent to a pure shear (110) a/4 [112]); in the normal spinel structure it is (100) a/4 [011]. Discrepancies between the theoretical conclusions and experimental data are discussed.
No takes yet. Share an insight, caveat, or question.
Veyssière et al. (1975) studied this question.