In this paper, a novel wafer-level hermetic packaging technology for heterogeneous device integration is presented. Hermetic sealing is achieved by low-temperature thermo-compression bonding using electroplated Au micro-sealing frame planarized by single-point diamond fly-cutting. The proposed technology has significant advantages compared to other established processes in terms of integration of micro-structured wafer, vacuum encapsulation and electrical interconnection, which can be achieved at the same time. Furthermore, the technology is also achievable for a bonding frame width as narrow as 30 μ m, giving it an advantage from a geometry perspective, and bonding temperatures as low as 300 °C, making it advantageous for temperature-sensitive devices. Outgassing in vacuum sealed cavities is studied and a cavity pressure below 500 Pa is achieved by introducing annealing steps prior to bonding. The pressure of the sealed cavity is measured by zero-balance method utilizing diaphragm-structured bonding test devices. The leak rate into the packages is determined by long-term sealed cavity pressure measurement for 1500 h to be less than 2.0 × 10 − 14 Pa m 3 s −1 . In addition, the bonding shear strength is also evaluated to be higher than 100 MPa.