Key result
Surgical removal resolves an unexpected bioprosthetic mitral valve thrombus during VA-ECMO prior to LVAD implantation.
Case Report (n=1)
No
Early transesophageal echocardiography is critical for detecting bioprosthetic valve thrombosis in patients on VA-ECMO support prior to LVAD implantation.
Answers are grounded in this paper and cite their sources.
Alerts clinicians to bioprosthetic valve thrombosis risk on VA-ECMO; hypothesis-generating for anticoagulation before LVAD.
Acute bioprosthetic valve thrombosis can occur after surgery and sometimes cause hemodynamic instability and cardiogenic shock. Risk factors for bioprosthetic valve thrombosis are hypercoagulability, atrial fibrillation, atrial dilatation, low cardiac function, and lack of anticoagulation therapy. The authors present a case of severe mitral stenosis due to bioprosthetic valve thrombus. The patient was diagnosed with dilated-phase hypertrophic cardiomyopathy and underwent mitral valve replacement. He required venoarterial extracorporeal membrane oxygenation (VA-ECMO) due to extremely low cardiac output and was scheduled for left ventricular assist device (LVAD) implantation. Transesophageal echocardiographic examination before LVAD implantation revealed severe mitral stenosis due to bioprosthetic mitral valve thrombus, which was not detected by transthoracic echocardiography in the intensive care unit and contributed to the low cardiac function. The thrombus was removed through an unscheduled left atriotomy before LVAD implantation. The possibility of bioprosthetic valve thrombosis must be considered when the patient is dependent on VA-ECMO support. Early transesophageal echocardiographic examination of the bioprosthetic valve may be helpful and contribute to surgical decision-making.
No takes yet. Share an insight, caveat, or question.
Imada et al. (2017) conducted a case report in Bioprosthetic mitral valve thrombus (n=1). VA-ECMO and LVAD implantation was evaluated. A 61-year-old man on VA-ECMO support developed severe mitral stenosis due to an unexpected bioprosthetic mitral valve thrombus, which was successfully removed before LVAD implantation.
Synapse has enriched 10 related papers. Consider them for comparative context: