Key result
Late bioprosthetic valve thrombosis is a rare cause of valve dysfunction that can present with an increasing transvalvular pressure gradient after anticoagulation termination.
Bioprosthetic valve thrombosis should be considered as a cause of valve dysfunction when transvalvular pressure gradient increases after anticoagulation termination.
Answers are grounded in this paper and cite their sources.
Raises suspicion for late thrombosis with rising gradients after anticoagulation stop; leaves open optimal duration and monitoring strategies.
Although clinically significant bioprosthetic valve thrombosis is rare, it should be considered a possible cause of valve dysfunction when there is an increasing transvalvular pressure gradient after anticoagulation is terminated. We describe a rare case of bioprosthetic mitral thrombosis in a 77-year-old woman 2 years after valve replacement and a maze procedure.
No takes yet. Share an insight, caveat, or question.
Jung et al. (2012) studied this question. Late bioprosthetic valve thrombosis is a rare cause of valve dysfunction that can present with an increasing transvalvular pressure gradient after anticoagulation termination.
Synapse has enriched 10 related papers. Consider them for comparative context: