A new method based on the “Inform” principle is presented enabling control of permanent‐magnet synchronous motors without speed‐ and position sensors. A special measurement procedure detects the electrical rotor angular position by using test signals generated by the inverter. The basic idea is to measure the different inductances in direct and quadrature axis due to saturation effects or construction. The sign of the magnetic flux is detected by shifting the magnetic set‐point with a certain armature current. Some possibilities of how to calculate the rotor angular position from test signals are given. Measurements using a DSP‐controlled drive verify the practical applicability of the new principle.
No takes yet. Share an insight, caveat, or question.
Manfred Schrödl (1993) studied this question.