Key result
Automated machine learning for CMR segmentation yields ~17% higher clinical quality scores than manual contouring.
Why the study?
Quantitative measures used to assess automated segmentation performance often do not reflect clinical acceptability, creating a need for quality-based assessment of automated CMR segmentation relevant to clinical practice.
Does automated contouring using a machine learning algorithm improve contour quality scores compared to manual contouring in short-axis cine CMR images?
Cross-Sectional (n=217)
Blinded to the source of the contour (manual vs automated)
Images were randomly presented to raters
Yes
Does automated contouring using a machine learning algorithm improve contour quality scores compared to manual contouring in short-axis cine CMR images?
Odds Ratio: 1.17 (95% CI 1.07–1.28)
Absolute Event Rate: 3.78% vs 3.78%
p-value: p=0.001
Automated machine learning algorithms for CMR segmentation produce contours of higher clinical quality than manual contouring, potentially improving clinical workflow and confidence in artificial intelligence.
Should not yet change CMR segmentation practice; leaves open prospective validation of clinical impact.
Background The quantitative measures used to assess the performance of automated methods often do not reflect the clinical acceptability of contouring. A quality-based assessment of automated cardiac magnetic resonance (CMR) segmentation more relevant to clinical practice is therefore needed. Objective We propose a new method for assessing the quality of machine learning (ML) outputs. We evaluate the clinical utility of the proposed method as it is employed to systematically analyse the quality of an automated contouring algorithm. Methods A dataset of short-axis (SAX) cine CMR images from a clinically heterogeneous population (n = 217) were manually contoured by a team of experienced investigators. On the same images we derived automated contours using a ML algorithm. A contour quality scoring application randomly presented manual and automated contours to four blinded clinicians, who were asked to assign a quality score from a predefined rubric. Firstly, we analyzed the distribution of quality scores between the two contouring methods across all clinicians. Secondly, we analyzed the interobserver reliability between the raters. Finally, we examined whether there was a variation in scores based on the type of contour, SAX slice level, and underlying disease. Results The overall distribution of scores between the two methods was significantly different, with automated contours scoring better than the manual (OR (95% CI) = 1.17 (1.07–1.28), p = 0.001; n = 9401). There was substantial scoring agreement between raters for each contouring method independently, albeit it was significantly better for automated segmentation (automated: AC2 = 0.940, 95% CI, 0.937–0.943 vs manual: AC2 = 0.934, 95% CI, 0.931–0.937; p = 0.006). Next, the analysis of quality scores based on different factors was performed. Our approach helped identify trends patterns of lower segmentation quality as observed for left ventricle epicardial and basal contours with both methods. Similarly, significant differences in quality between the two methods were also found in dilated cardiomyopathy and hypertension. Conclusions Our results confirm the ability of our systematic scoring analysis to determine the clinical acceptability of automated contours. This approach focused on the contours' clinical utility could ultimately improve clinicians' confidence in artificial intelligence and its acceptability in the clinical workflow.
No takes yet. Share an insight, caveat, or question.
Rauseo et al. (2022) conducted a cross-sectional in Cardiovascular diseases (DCM, HTN, HCM, IHD, LVNC, myocarditis) and healthy controls (n=217). Automated machine learning CMR segmentation algorithm vs. Manual segmentation was evaluated on Clinical quality score of contours (1 to 4) (OR 1.17, 95% CI 1.07-1.28, p=0.001). An automated machine learning algorithm for cardiovascular magnetic resonance segmentation produced contours with significantly higher clinical quality scores compared to manual segmentation (OR 1.17).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: