Answers are grounded in this paper and cite their sources.
AIM: To evaluate prospectively the clinical and radiographic outcomes after 5 years of early loading of 6-mm implants with a moderately rough (SLActive(®) ) surface supporting single crowns in the posterior regions. MATERIAL AND METHODS: Thirty-five consecutive patients received 40 SLActive(®) (Straumann) 6-mm implants with a diameter of 4.1 mm (n = 19) or 4.8 mm (n = 21). Insertion torque and resonance frequency analysis (RFA) were measured at implant installation. RFA was also measured at abutment connection. SynOcta abutments were tightened with 35 Ncm after 6 weeks of healing, and single porcelain fuse to metal crowns was cemented within 1 week. Implant survival rate and marginal bone loss were evaluated at various time intervals until 5 years after loading. The clinical crown/implant ratio was calculated as well. RESULTS: Two of 40 implants were lost before loading (incorporation rate 95%), and no further implant loss or technical complications were encountered during the 5-year follow-up period. A mean marginal bone loss of 0.7 ± 0.6 mm was found after 5 years of function. The clinical crown/implant ratio increased with time from 1.6 at the delivery of the prosthesis to 2 after 5 years of loading. CONCLUSION: Six millimeter implants with a SLActive(®) moderately rough surface supporting single crowns in the posterior region and loaded after 6-7 weeks maintained full function for at least 5 year with low marginal bone resorption.
No takes yet. Share an insight, caveat, or question.
Rossi et al. (2014) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: