Answers are grounded in this paper and cite their sources.
A method of using an isodose plotter to produce isodose charts in a water phantom containing bone, lung-equivalent material, or air cavities is described. It is shown that for 60Co γ rays and 4 MV X radiation standard isodose charts can be modified to fit the experimental results by the use of a simple set of rules to an absolute accuracy of about 2 per cent. Some isodose charts for conventional quality radiation in non-uniform phantoms are also discussed, but here the effects produced by the non-uniformity are more complex than with megavoltage radiation and corrections derived from simple rules are of limited value. In the second part of the paper, the rules for modifying megavoltage isodose charts are used to prepare some treatment plans for real body sections, and these are compared with conventional treatment plans where it is assumed that the body section consists entirely of soft tissue. It is shown that there is probably no clinically significant difference between the conventional and corrected d...
No takes yet. Share an insight, caveat, or question.
Greene et al. (1965) studied this question.