The measurements to be described here were made on a travelling-wave linear accelerator manufactured by Metropolitan-Vickers Co., Ltd. In this machine an electro-magnetic wave with an axial component of electric field is directed along a wave-guide so that electrons injected into the guide may have their energy increased as they move along with the wave. In order that the phase-velocity of the wave may be reduced to the velocity of the electrons, corrugations have to be made in the wall of the wave-guide. Suitable dimensioning of these corrugations ensures that the wave continues to accelerate the electrons as they increase from their initial energy of 50 kev till they strike the 2-mm.-thick transmission-type gold target with a final energy of 4 MEV, attained after travelling a distance of 1 meter. The waves, with a frequency of approximately 3,000 Mc∕S, are generated by a magnetron of 2 MW peak power operating with a pulse length of approximately 2 microseconds and a repetition rate of 350 pulses per second. Under these conditions, with a beam-flattening filter which gives a reasonably uniform field 30 cm. wide at 1 meter from the target, a dose rate of over 100 r per minute, measured in air, is obtained at that distance. Two parallel plate ionisation chambers are incorporated in the x-ray head, one being connected to a dose-rate meter and the other to a dosemeter in the control desk. Provision is made for terminating the exposure after a pre-set dose is reached. The equipment has been fully described by Miller and Flanders (1). The layout of the treatment, control, and apparatus rooms in any particular department is usually dictated by local geography and requirements, and will not be described. The treatment room is surrounded by concrete walls 2 feet 6 inches thick, except for one wall on which the direct beam of the x-rays may be incident, which is 5 feet thick. A direct viewing window is set in one wall above the control desk. This window is constructed from eighteen sheets of 1 1∕2-inch plate glass set in a bronze casting, the space between the sheets being filled with liquid paraffin to minimise internal reflection. Cerium oxide is incorporated in nine of the sheets nearest the treatment room to prevent discolouration from radiation. The effective area of the window is 21 × 16 inches. The design of the treatment couch is based on principles described by Flanders and Newbery (2), i.e., the vertical axis of rotation of the couch passes through a point 1 meter from the target, at which the x-ray beam axis and the horizontal axis of rotation of the accelerator gantry intersect. The x-ray beam can be swung from a position 20° beyond the vertical on one side to 120° beyond the vertical on the opposite side. To allow the gantry to reach this latter position, a section of the treatment room floor can be lowered.
No takes yet. Share an insight, caveat, or question.
Murison et al. (1957) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: