Key result
Specular optical reflectance yields refractive indices for transparent and absorbing fluids but deviates for turbid ones.
This study describes an optical method for measuring refractive indices of fluids, noting limitations when applied to highly heterogeneous turbid fluids.
Answers are grounded in this paper and cite their sources.
Optical method yields refractive indices for homogeneous fluids; leaves open reliable application to heterogeneous turbid samples.
A method is described for measuring the specular optical reflectance R( phi ) of the interface between a fluid and a glass prism, the incident and reflected light being in the glass, and the angle of incidence phi being varied about the critical angle. Transparent, absorbing and some turbid fluids give R( phi ) dose to theoretical predictions, and experimental reflectance data are analysed to give the real (n') and imaginary (n") refractive indices of the fluid. Other turbid fluids gave R( phi ) data that differed strongly from theoretical expectation. This is attributed to heterogeneity of the fluid on the optical wavelength scale, and problems of refractometry for such fluids are discussed.
No takes yet. Share an insight, caveat, or question.
Meeten et al. (1995) studied this question. Refractive index measurement by reflection near the critical angle was evaluated on Real and imaginary refractive indices derived from specular optical reflectance. Measuring specular optical reflectance near the critical angle successfully yielded refractive indices for transparent and absorbing fluids, but deviated for some turbid fluids due to heterogeneity.