Key result
Low inspired oxygen fails to reduce periprocedural myocardial injury vs high oxygen during TAVI.
Why the study?
Clinical outcomes of oxygen therapy remain inconsistent, and the relationship between inspired oxygen fraction during TAVI and clinical outcomes has not been well studied.
Does low inspired oxygen fraction (FIO2 0.3) reduce myocardial injury compared to high inspired oxygen fraction (FIO2 0.8) in adults undergoing transfemoral TAVI under general anesthesia?
RCT (n=62)
Double-blind
Block randomization
No
Does low inspired oxygen fraction (FIO2 0.3) reduce myocardial injury compared to high inspired oxygen fraction (FIO2 0.8) in adults undergoing transfemoral TAVI under general anesthesia?
Using a low fraction of inspired oxygen (0.3) during TAVI under general anesthesia did not significantly reduce periprocedural myocardial injury compared to a high fraction (0.8), though a marginal trend was observed.
Answers are grounded in this paper and cite their sources.
Does not support low FiO2 to reduce myocardial injury during TAVI; challenges oxygen toxicity assumptions and leaves optimal fraction open.
Background Oxygen therapy is used in various clinical situation, but its clinical outcomes are inconsistent. The relationship between the fraction of inspired oxygen (F I O 2 ) during transcatheter aortic valve implantation (TAVI) and clinical outcomes has not been well studied. We investigated the association of F I O 2 (low vs. high) and myocardial injury in patients undergoing TAVI. Methods Adults undergoing transfemoral TAVI under general anesthesia were randomly assigned to receive F I O 2 0.3 or 0.8 during procedure. The primary outcome was the area under the curve (AUC) for high-sensitivity cardiac troponin I (hs-cTnI) during the first 72 h following TAVI. Secondary outcomes included the AUC for postprocedural creatine kinase-myocardial band (CK-MB), acute kidney injury and recovery, conduction abnormalities, pacemaker implantation, stroke, myocardial infarction, and in-hospital mortality. Results Between October 2017 and April 2022, 72 patients were randomized and 62 were included in the final analysis (n=31 per group). The median (IQR) AUC for hs-cTnI in the first 72 h was 42.66 (24.82–65.44) and 71.96 (35.38–116.34) h·ng/mL in the F I O 2 0.3 and 0.8 groups, respectively (p=0.066). The AUC for CK-MB in the first 72 h was 257.6 (155.6–322.0) and 342.2 (195.4–485.2) h·ng/mL in the F I O 2 0.3 and 0.8 groups, respectively (p=0.132). Acute kidney recovery, defined as an increase in the estimated glomerular filtration rate ≥ 25% of baseline in 48 h, was more common in the F I O 2 0.3 group (65% vs. 39%, p=0.042). Other clinical outcomes were comparable between the groups. Conclusions The F I O 2 level did not have a significant effect on periprocedural myocardial injury following TAVI. However, considering the marginal results, a benefit of low F I O 2 during TAVI could not be ruled out.
No takes yet. Share an insight, caveat, or question.
Cho et al. (2023) conducted an RCT in Aortic stenosis (n=62). Low fraction of inspired oxygen (FIO2) vs. High fraction of inspired oxygen (FIO2 0.8) was evaluated on Area under the curve (AUC) for high-sensitivity cardiac troponin I (hs-cTnI) during the first 72 h following TAVI (p=0.066). Low inspired oxygen fraction compared to high fraction during transcatheter aortic valve implantation did not reduce periprocedural myocardial injury as measured by hs-cTnI AUC.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: