Key result
Computer-generated tailored discharge documents show equivalent patient comprehension to conventional information after EP procedures.
Why the study?
Shortened hospital admissions challenge healthcare professionals to provide necessary discharge instructions quickly, and while patient-tailored discharge information may improve comprehension, it can be time-consuming.
Does a computer-generated patient-tailored discharge document improve patient comprehension of discharge information in patients undergoing an electrophysiological procedure?
Observational (n=112)
Does a computer-generated patient-tailored discharge document improve patient comprehension of discharge information in patients undergoing an electrophysiological procedure?
A computer-generated patient-tailored discharge document provides equivalent comprehension to conventional methods while potentially reducing discharge preparation time for nursing staff.
May support tailored digital discharge tools in EP care; leaves open effects on adherence or outcomes in larger trials.
Objective The duration of hospital admissions has shortened significantly. This challenges healthcare professionals to provide the necessary information and instructions in a limited time. Patient-tailored discharge information may improve the patient's understanding of the discharge information but may also be time-consuming. The objective of this descriptive quality improvement study was to evaluate patient comprehension of discharge information using a novel computer-generated patient-tailored discharge document. Methods A prospective pre-post study comparing patient-tailored discharge information with conventional discharge information, for patients undergoing an electrophysiological procedure during two periods of six weeks between January and March 2016. Group I received conventional discharge information ( n = 55). Group II received a computer-generated, patient-tailored discharge document ( n = 57). Their comprehension of the discharge information was evaluated using a peer-reviewed questionnaire distributed among patients, comparing groups I and II using Likert scales. Nurses and nurse practitioners evaluated the use of personalized discharge information by means of a short survey. Results In terms of discharge information, comprehensibility was equivalent; however, an increase in comprehension was observed in patients seeking a telephone consultation with the cardiology department within one-week post-discharge. A reduction in discharge preparation time and an increased uniformity of discharge information were reported by nurses. Nurse practitioners found the web tool easy to use and time-saving. Conclusions In this study, computer-generated patient-tailored discharge information was equivalent to conventional discharge information. A more positive trend was seen for patients who initiated teleconsultation with the hospital within one-week post-discharge. This suggests that for this subgroup the patient-tailored discharge web tool might lead to an improvement in care. However, more research with a larger number of participants is needed to confirm this trend.
No takes yet. Share an insight, caveat, or question.
Wit et al. (2022) conducted an observational in Patients undergoing an electrophysiological procedure (n=112). Computer-generated patient-tailored discharge document vs. Conventional discharge information was evaluated on Comprehension of the discharge information. A computer-generated patient-tailored discharge document provided equivalent comprehensibility to conventional discharge information for patients undergoing electrophysiological procedures.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: