Key result
Continuous low-rate IV treprostinil proves feasible in a dog model with 1 catheter occlusion.
Why the study?
Does continuous low volume delivery of intravenous treprostinil via a miniature pump maintain catheter patency and adequate pharmacokinetics in a conscious dog model?
Does continuous low volume delivery of intravenous treprostinil via a miniature pump maintain catheter patency and adequate pharmacokinetics in a conscious dog model?
Continuous low-volume intravenous delivery of treprostinil via a miniature pump is feasible in a dog model, supporting its evaluation in patients with pulmonary arterial hypertension.
Does not support clinical use; leaves open feasibility of miniature-pump treprostinil delivery in pulmonary arterial hypertension.
PURPOSE: Two animal studies were conducted to determine the feasibility of infusing treprostinil via a central venous catheter at an infusion rate of 0.1 mL/hour. Currently treprostinil is administered intravenously at infusion rates of approximately 1.0 to 2.0 mL/hour to patients with pulmonary arterial hypertension, which reflects standard clinical practice to ensure line patency with continuous intravenous administration via a central venous catheter. METHODS: In a pilot study three male beagle dogs were administered 50 ng/kg/min of treprostinil continuously at an infusion rate of 0.1 mL/hr via the MiniMed 407C infusion pump for 21 days. In a definitive study, six male beagle dogs were administered 50 ng/kg/min of treprostinil continuously at an infusion rate of 0.1 mL/hr via the MiniMed 407C infusion pump for 60 days. In both studies 'no delivery' pump alarms were documented throughout the study in addition to pharmacokinetic data at specified time points. RESULTS: There were no documented occlusions in the 21-day pilot study. In the 60-day study one animal had a documented catheter occlusion after 16 days of therapy. Following reimplantation with a new catheter this animal did not have any additional occlusions for 40 days. No other animals in this study had any significant problems. In both studies, pharmacokinetic data were similar to that observed in previous animal studies evaluating treprostinil administration at the same dose and at higher infusion rates. CONCLUSION: These animal data support the evaluation of administering treprostinil at a low infusion rate via the MiniMed 407C infusion pump in patients with pulmonary arterial hypertension.
No takes yet. Share an insight, caveat, or question.
Laliberte et al. (2005) studied Pulmonary arterial hypertension (animal model) (n=9). Treprostinil via central venous catheter was evaluated on Catheter occlusions and pharmacokinetic data. Continuous intravenous delivery of treprostinil at a low infusion rate of 0.1 mL/hr was feasible in a dog model, with only one catheter occlusion observed over 60 days.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: