This paper proposes a four-degrees-of-freedom modulation scheme to mitigate the conduction and switching losses in a dual-active-bridge (DAB) series-resonant converter. Under wide-range variations in the voltage gain and output current, the increased reactive power and root-mean-square tank current can contribute significantly to the conduction loss in a DAB converter, while the occurrence of hard switching leads to a switching loss and an increased device stress. The proposed modulation scheme utilizes internal, external phase shifts, and switching frequency as modulation parameters to achieve zero reactive power, minimum-tank-current, and complete soft-switching operation. Analysis of the proposed modulation scheme is given for both buck- and boost-mode operations. The proposed modulation scheme is validated by means of a 1-kW experimental prototype of a DAB series-resonant converter operating at 100 kHz, designed to interface a supercapacitor with a rated output voltage of 48 V to a 250-V dc bus. The effectiveness of the proposed topology for charging/discharging a supercapacitor under wide-range variations in the voltage gain and output current is verified by simulations and experimental results. A maximum efficiency of 97.7% is recorded from the experimental prototype (The experimental setup used for measuring converter's efficiency is shown in the supplementary material).
No takes yet. Share an insight, caveat, or question.
Yaqoob et al. (2018) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: