Key result
Bedside EPS predicts AV block recurrence after TAVR with a ~100% negative predictive value.
Why the study?
Some patients recover from high-degree or complete AV block after TAVR, and electrophysiological study results for guiding permanent pacemaker implantation remain controversial.
Does bedside electrophysiological study using a temporary pacemaker predict recurrence of HAVB/CHB in patients who recovered from HAVB/CHB after TAVR?
Observational (n=11)
No
Does bedside electrophysiological study using a temporary pacemaker predict recurrence of HAVB/CHB in patients who recovered from HAVB/CHB after TAVR?
Answers are grounded in this paper and cite their sources.
Bedside electrophysiological study using a temporary pacemaker may help predict the recurrence of high-degree AV block or complete heart block in patients who initially recover after TAVR.
High-degree atrioventricular block (HAVB) or complete heart block (CHB) is a common complication associated with transcatheter aortic valve replacement (TAVR). However, some patients with HAVB/CHB recover with time. The results of electrophysiological studies (EPSs) using permanent pacemaker implantation (PPI) in patients with suspicious HAVB/CHB are considered controversial.This study aimed to evaluate whether HAVB/CHB induction at the bedside using a temporary pacemaker can predict recurrence in patients who had recovered from HAVB/CHB after TAVR.We enrolled a total of 11 patients who had recovered from HAVB/CHB and evaluated their electrophysiology using right ventricular pacing and/or procainamide administration.HAVB/CHB induction was positive. Three patients tested positive for HAVB/CHB, whereas 8 tested negative. The ejection fraction and the interval between HAVB/CHB onset and EPS were found to be significant. HAVB/CHB positive patients underwent PPI. A patient with a balloon-expandable valve tested positive just before recovery of CHB, but tested negative 5 days later and was included in the negative group. The 4 patients who tested negative received a cardiovascular implantable electric device (CIED). We observed HAVB/CHB in 2 patients who had previously tested positive after 3 months. Among those who tested negative, those with CIED had no HAVB/CHB, and others showed neither HAVB/CHB on electrocardiogram nor experienced syncope or sudden death.Our EPS revealed that HAVB/CHB induction may predict HAVB/CHB recurrence after TAVR. Valve type and EPS timing may affect the results.
No takes yet. Share an insight, caveat, or question.
Nauchi et al. (2021) conducted an observational in High-degree atrioventricular block or complete heart block after transcatheter aortic valve replacement (n=11). Positive bedside electrophysiological study (EPS) using a temporary pacemaker vs. Negative bedside EPS was evaluated on Recurrence of high-degree atrioventricular block or complete heart block. Bedside electrophysiological study using a temporary pacemaker predicted recurrence of atrioventricular block after TAVR with a 67% positive predictive value and 100% negative predictive value.