Answers are grounded in this paper and cite their sources.
Temperature control of samples constitutes a critical aspect in magnetron sputtering processes. Poor surface temperature uniformity can lead to film warping and delamination, ultimately reducing chip production yield. Quartz lamp infrared matrix heating is a widely used method in magnetron sputtering heating systems due to its controllability and ease of adjustment. However, the temperature uniformity across the sample surface is highly sensitive to lamp arrangement, and improper layouts can result in significant temperature gradients. To improve temperature uniformity, we developed a finite element simulation model calibrated with experimental heating data. Based on this model, eight optimized lamp arrangements were designed and simulated. The results indicate that positioning lamps closer to the center enhances the heating rate in the central region and reduces temperature disparities across the sample. An optimal lamp layout was proposed based on simulations, and experimental validation confirmed a 30.27 °C reduction in temperature variation compared to the original setup, demonstrating that surface temperature uniformity is improved by 38%