Key result
Patients undergoing head-upright tilt-table testing after January 2021 had reduced odds of a positive test for syncope and POTS.
Why the study?
The real-world use of head-upright tilt-table tests (HUTTs) in North America is not known.
Observational (n=1,063)
No
Despite an overall increase in the utilization of head-upright tilt-table testing, the diagnostic yield for syncope and POTS has significantly decreased in recent years.
Answers are grounded in this paper and cite their sources.
Lower tilt-table yield since 2021 may reflect referral shifts; leaves open whether testing indications require re-evaluation.
The real-world use of head-upright tilt-table tests (HUTTs) in North America is not known. This single-centre retrospective study in Toronto, Ontario, Canada reports on 1063 HUTTs conducted between 2014 and 2024. Use of the HUTT increased year over year, with a greater increase in HUTTs conducted as a result of a referral diagnosis of postural orthostatic tachycardia syndrome (POTS). Using specific diagnostic criteria for syncope and POTS, patients with either diagnosis who underwent testing, after January 2021 had an almost 50% reduction in the odds of a positive HUTT (syncope: odds ratio: 0.54, 95% confidence interval: 0.40-0.73 and postural orthostatic tachycardia syndrome: odds ratio: 0.51, 95% confidence interval: 0.28-0.95).
No takes yet. Share an insight, caveat, or question.
Souza et al. (2025) conducted an observational in Syncope and postural orthostatic tachycardia syndrome (POTS) (n=1,063). Testing after January 2021 vs. Testing before January 2021 was evaluated on Positive head-upright tilt-table test (HUTT) for syncope (OR 0.54, 95% CI 0.40-0.73). Patients undergoing head-upright tilt-table testing after January 2021 had reduced odds of a positive test for syncope and POTS.
Synapse has enriched 10 related papers. Consider them for comparative context: