Key result
Systemic thrombolysis and anticoagulation successfully resolve TIVAP-induced CRAT after 9 days.
Why the study?
Catheter-related right atrial thrombosis is a severe complication under-reported with totally implantable venous access ports, with most literature limited to hemodialysis patients.
Does a combination of systemic thrombolysis and anticoagulation therapy resolve catheter-related right atrial thrombosis in a patient with a TIVAP?
Case Report (n=1)
Does a combination of systemic thrombolysis and anticoagulation therapy resolve catheter-related right atrial thrombosis in a patient with a TIVAP?
Systemic thrombolysis combined with anticoagulation successfully resolved a large TIVAP-induced right atrial thrombus in a breast cancer patient.
Case report of CRAT with TIVAP in cancer; leaves open incidence, screening, and management strategies.
INTRODUCTION: As an under-reported, severe, and life-threatening complication, catheter-related right atrial thrombosis (CRAT) can appear at any age with any type of central venous catheter (CVC). However, most reports are limited to hemodialysis patients with CVC. Totally implantable venous access port (TIVAP) is widely used for the infusion of high-concentration chemotherapeutic drugs in cancer patients. However, these catheters may cause CRAT. CASE DESCRIPTION: A 27-year-old female patient with TIVAP was referred for neoadjuvant chemotherapy because of breast cancer. At 60 days after TIVAP implantation, routine transthoracic ultrasound examination confirmed a mass of 3.4 × 2.5 cm in the right atrium (RA). The mass was attached to the atrial wall and close to the catheter tip. Initially, we chose systemic anticoagulation therapy, but it failed. Subsequently, we decided to adopt a combination of systemic thrombolysis and anticoagulation therapy via a cubital vein. After 9 days of treatment, the thrombus disappeared, and the TIVAP was eventually removed. CONCLUSIONS: Systemic thrombolysis and anticoagulation therapy seemed to be safe and effective for asymptomatic patients who had TIVAP-induced CRAT. We should position the catheter tip at the junction of the Superior Vena Cava with the Right Atrium during the implantation procedure in cancer patients undergoing chemotherapy.
No takes yet. Share an insight, caveat, or question.
Zhang et al. (2021) conducted a case report in Catheter-related right atrial thrombosis (CRAT) (n=1). Systemic thrombolysis and anticoagulation therapy was evaluated on Thrombus resolution. Systemic thrombolysis and anticoagulation therapy successfully resolved a 3.4 × 2.5 cm right atrial thrombus after 9 days of treatment in a patient with TIVAP-induced CRAT.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: