This is the authors' abstract. We don't add key points for this paper.
The influence of silica fume on concrete properties represents an important technical research. In general, silica fume tends to improve both mechanical characteristics and durability of concrete. Thus the electrical properties of concrete containing silica fume can be studied to clarify its physical performance during hydration. The electrical conductivity of neat cement, mortar and concrete pastes was measured during setting and hardening. The ordinary Portland cement was partially replaced by different amounts of silica fume by weight. The changes in the electrical conductivity were reported during setting and hardening after gauging with water. The results of this study showed that the electrical conductivity can be used as an indication for the setting characteristics as well as the structural changes of the hardened pastes made with and without silica fume.