Answers are grounded in this paper and cite their sources.
For phase-locked-loop synchronization (PLL-Syn) based Weak-Grid connected Voltage Source Converter (WG-VSC) system under asymmetric grid faults, published works mainly focus on existing of equilibrium point and small signal stability, which cannot address PLL-Syn transient stability problems. For the first time, we have proposed an analytical solution to the question of “Whether the WG-VSC system can reach to a new available equilibrium point (EP) of fault-on state from original EP of pre-fault state without loss of PLL-Syn transient stability under asymmetric faults?”. Dual-sequence current injections feasible region (CIFR) of WG-VSCs in positive and negative sequence current injection space is defined firstly. Then, by consideringPLL-Syn transient stability constraint, Maximum available current constraint, and PCC Voltage constraint, an analytical expression of CIFR has been obtained. Finally, experiments results based on detailed switching model in RT-BOX hardware-in-loop platform have been provided to verify the CIFR constructed in this paper. It should be noted that the work of this paper can not only address PLL-Syn transient stability problems of WG-VSC system under asymmetric faults, but also can pave the way for asymmetric fault ride-through control considering transient stability constraints.
No takes yet. Share an insight, caveat, or question.
Li et al. (2022) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: