Key result
Suprasternal aortic access for TAVR achieves 100% VARC-2 procedural success without complications in early cases.
Why the study?
Does the SuprAA System for direct transaortic TAVR provide procedural success and safety in patients with severe symptomatic aortic stenosis?
Case Report (n=4)
Does the SuprAA System for direct transaortic TAVR provide procedural success and safety in patients with severe symptomatic aortic stenosis?
The SuprAA System provides a safe and effective minimally invasive suprasternal approach for direct transaortic TAVR, avoiding sternotomy and thoracotomy in a first-in-man experience.
Answers are grounded in this paper and cite their sources.
Hypothesis-generating for suprasternal transaortic TAVR access; larger prospective studies needed before clinical adoption.
OBJECTIVES: Direct aortic deployment of a transcatheter aortic valve eliminates the need to traverse the aortic arch with the valve delivery system, enables placement of large sheaths in the aorta and innominate artery, provides maximal precision during deployment and ensures a safe, conventional surgical aortotomy closure. We describe the initial experience with the Suprasternal Aortic Access System (SuprAA System, Aegis Surgical Ltd, Dublin, Ireland) for direct transaortic/innominate valve delivery. METHODS: Patients with severe, symptomatic aortic stenosis who were candidates for transcatheter aortic valve replacement (TAVR) via a direct transaortic approach were enrolled in the SuprAA-TAVR First-in-Man Study. Under general anaesthesia, the innominate artery and aortic arch were exposed in each patient, using the SuprAA System via a 2.5-cm incision directly above the sternal notch. The TAVR delivery sheath was positioned and the transcatheter valve deployed routinely under fluoroscopic guidance. Upon sheath removal, haemostasis at the aortotomy site was confidently secured using a double purse-string suture closure. All were extubated immediately. A meta-analysis of the direct aortic approach was done for comparison. RESULTS: Four male patients (mean 82.5 years) underwent SuprAA-TAVR (2 CoreValve; 2 SAPIEN). Anatomical visualization was excellent and suprasternal valve deployment was accurate regardless of sheath size with 100% Valve Academic Research Consortium-2 procedural success. The average total procedure time was 109.5 min without perioperative wound or vascular complications. CONCLUSIONS: The SuprAA System provides direct aortic/innominate access without sternal or thoracotomy incision. Patient recovery to normal activity is maximized, sheath size limitations are eliminated and valve deployment is precise. This innovative system creates a new and exciting minimally invasive approach for high-risk patients with aortic stenosis.
No takes yet. Share an insight, caveat, or question.
Kiser et al. (2015) conducted a case report in severe, symptomatic aortic stenosis (n=4). Suprasternal Aortic Access System (SuprAA System) was evaluated on Valve Academic Research Consortium-2 procedural success. The Suprasternal Aortic Access System for direct transaortic TAVR achieved 100% VARC-2 procedural success in 4 male patients with severe aortic stenosis, without perioperative complications.