Key result
Small amplitude mechanical vibration induces LV functional depression that strongly correlates with EF.
Why the study?
Does small amplitude mechanical vibration induce functional depression (VID) that correlates with contractility in canine models and patients undergoing cardiac catheterization?
Does small amplitude mechanical vibration induce functional depression (VID) that correlates with contractility in canine models and patients undergoing cardiac catheterization?
Small amplitude mechanical vibration induces a functional depression (VID) that correlates with ejection fraction, suggesting potential utility as a diagnostic tool for evaluating mild heart failure.
VID may aid contractility assessment in mild HF; leaves open diagnostic utility pending prospective validation.
Small amplitude mechanical vibration has been reported to depress the function of the isolated left ventricle in an amplitude dependent manner. We examined, 1) contractility and preload dependency of the magnitude of functional depression (VID) by applying 50 Hz, 2 mm amplitude vibration to the epicardium of the canine left ventricle and 2) whether VID is present in the failing human ventricle. The magnitude of VID was independent of preload in the physiological range of LV volume showing peak LV pressure greater than 75 mmHg, and VID was correlated with Emax at each inotropic state. In the in-situ condition, VID appeared only in the failing condition with a sensitive increase at a mild level of heart failure. In a study during routine cardiac catheterization (n = 27), the presence of VID has been demonstrated in the human ventricle (n = 18). The magnitude of VID was correlated with ejection fraction (EF) as, VID in peak LV pressure (mmHg) = 80.6 - 110 x EF, r = 0.84, p less than 0.01 in patients with EF less than or equal to 0.7 (n = 14). Therefore, we concluded that VID could be a clinical tool for evaluation of mild heart failure.
No takes yet. Share an insight, caveat, or question.
Koiwa et al. (1992) studied Heart failure (n=27). Small amplitude mechanical vibration was evaluated on Correlation between magnitude of vibration-induced functional depression (VID) and ejection fraction (EF) (r = 0.84, p=<0.01). Small amplitude mechanical vibration induced functional depression in the human ventricle, which correlated with ejection fraction (r = 0.84, p < 0.01) in patients with EF ≤ 0.7.