This study reports the development, fabrication, outdoor deployment, and in-depth calibration of a polymer-based microwave sensor using silane-functionalized, hyperbranched polyethyleneimine (HBPEI-Silane) for detecting carbon dioxide (CO₂) at ppm concentrations under real environmental conditions. Among all possible gas reaction pathways of HBPEI-Silane, an advanced sensitivity analysis of the outdoor measurements coupled with Bayesian calibration demonstrated a strong sensitivity towards CO₂, with NO₂ acting as a significant interferent. The enhanced CO₂ sensitivity is attributed to the high density of tertiary amine groups in HBPEI and to its low humidity sensitivity conferred by the fluorinated silane groups. Altogether, the sensor achieved a 3σ-resolution toward CO₂ of approximately 20 ppm, with mean absolute prediction errors ranging from 4.5 to 7 ppm, which compares favorably with both commercial devices and the scientific state of the art. These results highlight the potential of HBPEI-Silane-functionalized microwave sensors for scalable and low-cost urban CO₂ monitoring under ambient outdoor conditions