Answers are grounded in this paper and cite their sources.
The application of a pulse-compression technique for the ultrasonic inspection of forged steel structures with high attenuation and large dimensions is presented. The performance of such a technique is theoretically analysed and validated experimentally by exploiting linear chirp signals. Based on the preliminary results, it is found that the strategy achieves a significant enhancement of the signal-to-noise ratio and then of the inspection capability. A further increase in performance can be achieved by exploiting signal processing and by developing proper hardware.
No takes yet. Share an insight, caveat, or question.
Ricci et al. (2012) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: