Key result
Fluid-structure model evaluates hemodynamic effects of concomitant aortic and subaortic stenosis on aortic valve function.
A fluid-structure interaction model was developed to study the aortic valve in the presence of subaortic stenosis.
Answers are grounded in this paper and cite their sources.
FSI model of dual stenosis suggests altered valve dynamics; leaves open clinical translation pending validation.
The concomitant presence of aortic stenosis (AS) and subaortic stenosis (SAS), most often due to a protrusion of the hypertrophied interventricular septum in the left ventricular outflow tract, may...
No takes yet. Share an insight, caveat, or question.
Guivier et al. (2005) studied this question. A fluid-structure interaction model evaluated the hemodynamic effects of concomitant aortic and subaortic stenosis on aortic valve function.
Synapse has enriched 10 related papers. Consider them for comparative context: