Key result
IVUS-guided bumper wire technique achieves a low 4.4% geographic miss rate in aorto-ostial stenting.
Why the study?
Procedural and long-term outcomes of the bumper wire technique with IVUS assessment for challenging aorto-ostial interventions had not been investigated.
Does the bumper wire technique with IVUS assessment prevent geographic miss in patients undergoing aorto-ostial stenting?
Cohort (n=45)
No
Does the bumper wire technique with IVUS assessment prevent geographic miss in patients undergoing aorto-ostial stenting?
The bumper wire technique with IVUS guidance for aorto-ostial stenting is associated with a low rate of geographic miss and favorable short-term clinical outcomes.
May reduce geographic miss in aorto-ostial stenting; hypothesis-generating pending randomized confirmation.
Background: Aorto-ostial interventions are challenging due to the limitations of contemporary equipment, imprecise ostial demarcation, and problematic ostial lesion characteristics. Suboptimal stent placement is common and portends worse clinical outcomes. Procedural and long-term outcomes of the bumper wire technique with intravascular ultrasound (IVUS) assessment have not been investigated. Methods: A single-center retrospective study was conducted. Patients who underwent ostial lesion percutaneous coronary intervention (PCI) with the bumper wire technique between January 2019 and September 2020 were identified. The primary endpoint was to determine the geographic miss rate defined by inadequate ostial coverage or excess stent protrusion of > 2 mm by IVUS or angiography. The secondary endpoint was target lesion failure (TLF) at 6 months after PCI, defined as the composite of cardiovascular death, target vessel myocardial infarction (MI), and target lesion revascularization. Results: In total, 45 patients were identified. The average age was 71.7 years old, and 85.4% were men. Indication for PCI was acute coronary syndrome in about a third of patients. Twenty-six patients had left main ostial lesions and 19 patients had right coronary artery ostial lesions. Geographic miss was detected in two patients (4.4%): one patient (2.2%) had excess proximal stent protrusion and one patient (2.2%) had an ostial miss. Six patients were lost to follow-up. TLF, stroke, or major bleeding were not observed in any of the patients. Conclusion: The bumper wire technique is safe and efficient with low rates of geographic miss or adverse clinical outcomes. This is the first study to confirm precise aorto-ostial stent implantation with the bumper wire technique using IVUS confirmation.
No takes yet. Share an insight, caveat, or question.
Reddy et al. (2022) conducted a cohort in Aorto-ostial coronary lesions (n=45). Bumper wire technique with intravascular ultrasound (IVUS) was evaluated on Geographic miss rate defined by inadequate ostial coverage or excess stent protrusion of > 2 mm by IVUS or angiography. The bumper wire technique with intravascular ultrasound guidance for aorto-ostial stenting resulted in a low geographic miss rate of 4.4%.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: