Reviews procedural techniques and specialized devices for precise stent placement in ostial coronary lesions, highlighting strategies to optimize clinical outcomes.
Accurate stent placement is known to be hampered by the anatomical nature of percutaneous coronary intervention (PCI) of ostial lesions, such as aorta-ostial lesions and Medina 001 bifurcation lesions. The Ostial Pro device, the aorta floating wire technique, the stent pull-back technique, the Szabo (tail-wire) techniques, the marker wire technique, the T-stent and small protrusion technique, the cross-over 1-stent technique, and new dedicated ostial stents are some of the techniques used to achieve perfection in precise ostial stent placement. The current state of knowledge about ostial PCI and novel approaches for optimizing these procedures are compiled in this review.
No takes yet. Share an insight, caveat, or question.
Dash et al. (2024) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: